Skip to content

Sync Triggers

Goal

Manually trigger a data synchronisation for LEI or master data when needed outside the normal daily schedule.

Prerequisites

  • You are signed in to Axiom with the Admin role.

Background

Axiom runs an automated daily sync at 2 AM to pull the latest data from GLEIF and other upstream sources. Use a manual sync trigger when:

  • An urgent data update is required before the next scheduled sync.
  • A scheduled sync has failed and needs to be re-run.
  • You are setting up a new environment and need to populate data immediately.
  • An upstream data source has published a correction that you need to apply sooner.

The LEI sync automatically pre-synchronises four GLEIF reference code lists (registration authorities, entity legal forms, organizational roles, and legal jurisdictions) before processing LEI Level 1/2 data. These reference lists ensure coded fields in LEI records display their full human-readable names in the UI.

Steps

Trigger a sync

  1. Click Admin in the top navigation.
  2. Select Sync Triggers from the admin menu.
  3. The page lists available sync jobs, for example LEI Full Sync or Master Data.
  4. Review the Last Run and Status columns to see when each job last ran and whether it succeeded.
  5. Click Trigger Sync next to the job you want to run.
  6. A confirmation prompt appears. Click Confirm to proceed.
  7. The job status changes to IN_PROGRESS.

Monitor sync progress

After triggering a sync:

  1. Stay on the Sync Triggers page. The status column updates automatically.
  2. The status will transition through IN_PROGRESSCOMPLETED (or FAILED).
  3. If the job reaches FAILED, review the failure category shown on the page and check with your data operations team if the issue persists.

Re-run a failed sync

  1. Locate the failed sync job on the Sync Triggers page.
  2. Click Trigger Sync to start a new run.
  3. If failures recur, escalate to your Axiom administrator or support team.

Expected result

The sync job completes with status COMPLETED. Updated data is available in the relevant module (for example, new or amended LEI records appear in the LEI Records page).

Common issues

IssuePossible causeResolution
Sync shows FAILED immediatelyUpstream source is unavailableWait a few minutes and try again; check GLEIF status if LEI sync
Status does not updatePage may not be auto-refreshingManually refresh the page
Trigger button is disabledAnother sync for that job is already runningWait for the current run to complete
Data not appearing after COMPLETEDCache delay or delta processingAllow a few minutes; hard-refresh the target module page